Emergency lighting is required to provide a sufficient level of illumination for persons to see their way to safety in the event of failure of the normal lighting, specifically during the hours of darkness.
A wide choice of fittings are available from basic bulkhead versions to architecturally pleasing alternatives.
Non-maintained emergency light fittings only illuminate in the event of a power failure.
Maintained emergency light fittings can be switched to illuminate normally and in the event of power failure.
Emergency lighting is required to be tested on an ongoing basis and Fixfire® installs simple test key points to facilitate this routine task without disrupting normal operation.
KeyCall® is a revolutionary patent-granted Key Operated Fire Alarm Activation Device which has been developed specifically for ‘approved’ applications where standard fire alarm call points would be vulnerable to abuse. Developed by Fixfire® in response to growing demand from the Mental Health Care sector, KeyCall® is a revolutionary one-piece analogue addressable key operated manual call point.
Compatible with a wide range of Conventional and Addressable Fire Alarm Systems.
KeyCall® accepts a Euro-Profile style cylinder
Typically suited/keyed-alike cylinders are fitted so that authorised persons can activate KeyCall® using their standard door key.
Key ‘Click-latch’ mechanism ensures key ‘latches’ in correct position to activate Fire Alarm System.
Anti-ligature low-profile flush-mounting design.
Neat minimalistic one piece construction incorporating Fire Alarm interface module.
Red fire indicator illuminates when KeyCall® is activated.
Compatible with a wide range of Conventional and Addressable Fire Alarm Systems
Applications include:
- Prisons
- Mental Healthcare
- Special Educational Needs (SEN) School
British Standard Design requirements...
- Install AFD to voids greater than 800mm
- Treat downward projections exceeding 10% of the void depth as wall
BS5839-Part 1:2013 states:
22.2d) If the system Category is such that automatic fire detection should be provided in any area that contains a horizontal void of 800 mm or more in height, automatic fire detection should also be provided in the void.
22.3j) Ceiling obstructions, such as structural beams, deeper than 10% of the overall ceiling height should be treated as walls [see Figure 10a)]. NOTE 10 Within horizontal voids, beams or obstructions that are deeper than 10% of the overall depth of the void regardless of whether the void is above the ceiling or below the floor, ought to be treated as walls that subdivide the void.
VoidAlert Remote Indicator
Related Downloads
Click a sector to find out more
Emergency lighting is required to provide a sufficient level of illumination for persons to see their way to safety in the event of failure of the normal lighting, specifically during the hours of darkness.
A wide choice of fittings are available from basic bulkhead versions to architecturally pleasing alternatives.
Non-maintained emergency light fittings only illuminate in the event of a power failure.
Maintained emergency light fittings can be switched to illuminate normally and in the event of power failure.
Emergency lighting is required to be tested on an ongoing basis and Fixfire® installs simple test key points to facilitate this routine task without disrupting normal operation.